- TAT Indicator Blank:
Notes:
If the TAT indicator is blank, and you have problems with other systems such as “A” channel Autopilot and/or Flt. Director, or Ground Prox, then replace #1 ADC. If the TAT indicator is blank and no problems with the other systems that receive digital info from ADC #1 then:
1.Replace indicator.
2.Check for power to the indicator.
3.Check data bus wiring from #1 ADC to indicator.
TAT INFORMATION:
Circuit Breakers:TAT indicator: P18-2 = A7.
Capt Air data Computer 26VAC: P18-2 = A9.
Capt Air data Computer 115VAC: P18-2 = A8.
F/O's Air data Computer 26VAC: P6-1 = B6.
F/O's Air data Computer 115VAC: P6-1 = B7.
TAT probe heater 115vac: P18-3 = C5.
Applicable deferrals 34-5=Total Air Temperature Indication.