- Note #1
If ACT#2 is installed, when the ACT #1 is full (5020LBS max), the ACT fuel inlet valve closes and ACT#2 fuel inlet valve opens.
Steps to XFR Fuel From Wings to ACT:1.On the wing, power up the Defuel/Refuel panel and perform a high level sensing test.
2.On the wing Defuel/Refuel panel (800VU) put the mode select switch in the "Defuel XFR" position.
3.On the wing ACT Defuel/Refuel panel (801VU), set the applicable(or both) ACT refuel valve switch to the "OPEN" position. Set the" FQI SELECT CTR/ACT" switch to the applicable ACT position.
4.In the cockpit, push in the XFEED P/BSW, "ON" and "OPEN" light illuminate.
5.In the cockpit set applicable (or both) wing tank pump #1 and #2 to "ON", and set both Left and Right center tank XFR P/BSW to "OFF".
6.Monitor the fuel level of the ACT on the Fuel quantity indicator 6QT on the refuel panel. (maximum 5020lbs).
7.When fuel level of ACT's are correct, on the wing, shut the ACT refuel valves and put the mode select switch to the "OFF" position.
8.In the cockpit turn "OFF" the wing tank pumps. Push the XFEED P/BSW, "ON" & "OPEN" light extinguishes.
Cockpit Control Panel
Wing Defuel/Refuel Panel
Click Below Links For Resizable Images