- Aircraft configuration prior to reset:
No specific
Circuit breakers to reset:None.
Steps to clear warning:First select FADEC’s on then off to reset memory. Check the master chip detector and scavage filters for contamination. Then run engine at idle making sure the oil firlter clog message doesn’t appear. Recheck chip detector and filter again.
Reset duration:N/A.
Results of power up test or reset:Pass: N/A.
Fail: N/A.
Notes:This message could appear momentarily if OAT is below freezing.
Sign off:CFM=TSM79-00-00-810-820.
V2500=TSM79-30-00-810-803.
Applicable deferrals:MEL79-35-01=Engine Oli Filter Clog Message.