- Aircraft configuration prior to reset:
Aircraft on ground.
Circuit breakers to reset:None.
Steps to clear warning:Test thrust reversers with engines running.
Reset duration:N/A.
Results of power up test or reset:Pass: N/A.
Fail: N/A.
Notes:See TSM 78-00-00-810-802, Thurst reverser test without CFDS, Engines running.
Sign off:AMM78-31-00-710-04301. (Test with engines running)
Applicable deferrals:MEL78-30-01=Thrust Reverser Systems.