- Aircraft configuration prior to reset:
Aircraft on ground.
Circuit breakers to reset:None.
Steps to clear warning:Shut down engine. Put engine mode select switch to IGN, wait 15 seconds, then back to norm. If no faults, start engines.
Reset duration:N/A.
Results of power up test or reset:Pass: N/A.
Fail: N/A.
Notes:To prevent fault, select FADEC’s on from the 50VU maintenance panel prior to mode select switch to IGN.
Sign off:CFM=AMM78-31-00-710-042.
V2500=AMM78-31-00-710-042.
Applicable deferrals:MEL78-30-01=Thrust Reverser Systems.