- Aircraft configuration prior to reset:
No specific
Circuit breakers to reset:None.
Steps to clear warning:Read the specific data report from the MCDU=(CFDS/INST/EIS1/XLOAD(optional)/ENGINE).
Reset duration:N/A.
Results of power up test or reset:Pass: N/A.
Fail: N/A.
Notes:If the valve of one of these parameters is higher than the max limit, the report also shows how long (in seconds) the associated parameter was at that limit. If no overlimit condition occured, there is no time indication.
CFM=N1 speed >104 and N2 speed >105 will require inspections. T/S per TSM
V2500=N1/N2=100% 5465RPM/14,915RPM will require inspections.
You can reset these values if necessary. Push the line key adjacent to the “RESET MAX VALUES” then “CONFIRM RESET” indications.
Sign off:CFM=TSM73-00-00-810-850.
V2500=AMM71-00-00-860-010.
Applicable deferrals:No MEL.