- Aircraft configuration prior to reset:
Aircraft on ground, engines stopped.
Circuit breakers to reset:
Steps to clear warning:If this alert triggers at engine start, apply the following procedures:
1. Aircraft on ground.
2. Set ENG MASTER SW (affected) to off.
3. Confirm ENG (FADEC) GND PWR (affected) pb-sw to OFF. Wait appprox 1 minute in order to have N2 below 5%.
4. Cycle/Reset above affected C/B's.
5. After ECU power-up sequence, consider a engine dry crank (if applicable).
6. Restart the engine.
Reset duration:2 seconds.
Results of power up test or reset:Pass: Fault Clears
Fail: Fault remains.
Notes:No notes at this time.
Sign off:AMM73-22-00-710-040.
Applicable deferrals:No MEL.