- Aircraft configuration prior to reset:
No specific
Circuit breakers to reset:None.
Steps to clear warning:Recovery of EPR on both engines may be attemped by switching off each engine’s N1 mode switch.
Reset duration:N/A.
Results of power up test or reset:Pass: N/A.
Fail: N/A.
Notes:If EPR was fluctuating, check PFR for associated failures.P2/T2 or P5 failures = check associated lines for leaks.
Sign off:AMM73-22-00-710-040.
Applicable deferrals:No MEL.