- Aircraft configuration prior to reset:
Aircraft on ground, engines stopped.
Circuit breakers to reset:
Steps to clear warning:Open associated breaker for 1 second, then reset. If you have dual EIU faults, perform a FADEC (A/B) bite, then select start cycle rotary switch from norm to crank, wait 14 seconds and return to norm, wait 5 min, then pull ENG 1/2 oil pressure CB, reset after 5 seconds
Reset duration:2 seconds.
Results of power up test or reset:Pass: Fault Clears
Fail: Fault remains.
Notes:No notes at this time.
Sign off:AMM73-22-00-710-040.
Applicable deferrals:No MEL.