- Aircraft configuration prior to reset:
No specific
Circuit breakers to reset:None.
Steps to clear warning:Read the specific data report from the MCDU=(CFDS/INST/EIS1/XLOAD(optional)/ENGINE).
Reset duration:N/A.
Results of power up test or reset:Pass: N/A.
Fail: N/A.
Notes:If the valve of one of these parameters is higher than the max limit, the report also shows how long (in seconds) the associated parameter was at that limit. If no overlimit condition occured, there is no time indication.
Check history, if more than 5 hits within the first 25 cycles of the first hit, the exceedance condition must be idenified.
You can reset these values if necessary. Push the line key adjacent to the “RESET MAX VALUES” then “CONFIRM RESET” indications.
Sign off:CFM=TSM73-00-00-810-849, AMM72-00-00-200-008.
V2500=TSM73-22-00-810-861, AMM71-00-00-710-014.
Applicable deferrals:No MEL.