- Aircraft configuration prior to reset:
Aircraft on ground.
Circuit breakers to reset:None.
Steps to clear warning:
After loading 20TX, must disconnect loader for 3 minutes prior to loading 22TX, and again prior to loading 24TX.
Reset duration:N/A.
Results of power up test or reset:Pass: Software loads.
Fail: Software will not load.
Notes:Must load ATSU in order, 20TX, 22TX, 24TX. Adhere to manual loading procedure.
Sign off:AMM46-21-00-740-001.
Applicable deferrals:MEL23-24-01=ACARS.
MEL46-21-01=ATSU.