- Aircraft configuration prior to reset:
Aircraft on ground, emergency electrical generator test recently performed.
Circuit breakers to reset:
Steps to clear warning:Open both FWC breaker for 5 seconds, then reset. If no help reset both BMC’s (D11,D12,Z22,Z23) and FWC breakers again. If no help check BMC for faults.
Reset duration:90 seconds, triple click.
Results of power up test or reset:Pass: Message disappears.
Fail: Message remains. Check BMC for faults.
Notes:This fault is latched after Emergency Generator test.
Sign off:AMM36-11-00-740-001 (BMC TEST).