- Aircraft configuration prior to reset:
None specfic.
Circuit breakers to reset:
Steps to clear warning:Open associated breaker for 3 seconds, then reset. If no help, reset CIDS thru PTP or MCDU.
Reset duration:2 seconds.
Results of power up test or reset:Pass: Lights turn on.
Fail: Fault remains.
Notes:If a couple successive rows of cabin lights won’t turn on, associated DEU is failed.
Sign off:AMM33-21-00-710-001 (lights test).
AMM23-73-00-740-005 (CIDS bite).
Applicable deferrals:MEL23-73-02=DEU#A.
MEL33-21-01=Cabin Light System.