- Aircraft configuration prior to reset:
Aircraft on ground.
Circuit breakers to reset:
Steps to clear warning:Open associated breaker for 1 seconds, then reset.
Reset duration:2 seconds.
Results of power up test or reset:Pass: Fault clears.
Fail: Fault remains.
Notes:LGCIU #1 drives landing gear panel lights. also remember probes and window heat is driven to full hot when LGCIU breakers are open.
Sign off:AMM32-69-00-740-001
Applicable deferrals:MEL32-31-01=LGCIU