- Aircraft configuration prior to reset:
Aircraft on ground, not moving.
Circuit breakers to reset:
Steps to clear warning:First, select the anti-skid/NWS off, then on. Second open associated circuit breaker for 5 seconds, then close.
Reset duration:3 seconds.
Results of power up test or reset:Pass: Fault clears.
Fail: Fault remains.
Notes:No notes at this time.
Sign off:AMM32-46-00-740-001.
Applicable deferrals:MEL32-42-03=BSCU.