- Aircraft configuration prior to reset:
Aircraft on ground, doors shut, one engine started.
Circuit breakers to reset:
Steps to clear warning:Make sure “ALL” pushbutton light on ECAM control panel is extinguished. Move sidestick, If flight control page doesn’t auto display, open FWC #1 breaker and try again. If successful, FWC is culprit.
Reset duration:50 seconds.
Results of power up test or reset:Pass: Fault message is no longer displayed, flight control page auto popup functions normally.
Fail: Fault remains.
Notes:If any page on the ECAM control panel is manually selected, the auto-function is not operative.
Sign off:AMM31-50-00-710-002.
Applicable deferrals:MEL31-63-03=ECAM Memo Display.