- Aircraft configuration prior to reset:
Aircraft on ground, engines stopped.
Circuit breakers to reset:
Steps to clear warning:
Open associated breakers for 10 seconds, then reset.
Reset duration:
40 seconds.
Results of power up test or reset:Pass: ACMS message clears.
Fail: Fault remains.
Notes:
ACMS = Aircraft Condition Monitor Systems.
Sign off:AMM31-36-00-710-001
Applicable deferrals:MEL31-00 Class 2 Maintenance Message
