- Aircraft configuration prior to reset:
On ground.
Circuit breakers to reset:
Steps to clear warning:Open associated breakers for 5 seconds, then reset.
Reset duration:5 seconds.
Results of power up test or reset:Pass: ECAM warning clears, display unit works.
Fail: Fault remains.
Notes:Use switching panel 8VU to display DMC #3 images.
Sign off:AMM31-60-00-710-001. (EIS start)
Applicable deferrals:MEL31-63-02=Display Management Computers.