- Aircraft configuration prior to reset:
Aircraft on ground. Hydraulics depressurized.
Circuit breakers to reset:
Steps to clear warning:
First, reset applicable SEC pushbutton. If no help, open
associated breaker for 5 seconds, then reset. The pushbutton to remain in "ON" postion during breaker reset.
Reset duration:
20 seconds.
Results of power up test or reset:Pass: Fault clears.
Fail: Fault remains.
Notes:
If Hydraulics are pressurized, pushbutton reset will
not be successful. SEC #1 controls spoilers 3 & 4. SEC #2 controls spoilers 5. SEC #3 controls spoilers 1 & 2.
Sign off:AMM27-94-00-710-001 (SEC #3).
AMM27-94-00-710-002 (SEC #1).
AMM27-94-00-710-003 (SEC #2).
Applicable deferrals:MEL27-92-01=SEC’s.
MEL27-92-02=GND Spoilers.