- Aircraft configuration prior to reset:
On ground, hydraulics depressurized.
Circuit breakers to reset:None
Steps to clear warning:Reset wing tip brakes though MCDU/CFDS/SFCC/TEST/RESET.
Reset duration:30 seconds.
Results of power up test or reset:Pass: Fault clears.
Fail: Fault remains.
Notes:After reset of wing tip brakes, fault message clears.
Sign off:AMM27-51-00-710-002.