- Aircraft configuration prior to reset:
On ground, hydraulics depressurized.
Circuit breakers to reset:
Steps to clear warning:
Open circuit breakers for 5 second, then close.
Reset duration:
20 seconds.
Results of power up test or reset:Pass: Fault clears.
Fail: Fault remains.
Notes:
FCDC=Flght Control Data Concentrators.
Sign off:AMM27-96-00-710-001.
Applicable deferrals:MEL27-95-01=FCDC.