- Aircraft configuration prior to reset:
Aircraft on ground.
Circuit breakers to reset:
Steps to clear warning:First, reset applicable ELAC pushbutton. If no help, open associated breaker for 5 seconds. Pushbutton to remain in “ON” position during breaker reset.
Reset duration:20 seconds.
Results of power up test or reset:Pass: Fault clears.
Fail: Fault remains.
Notes:ELAC #1 controls left outboard (Blue) and right inboard (Green) aileron servos. ELAC #2 controls Left inboard (Green) and right outboard (Blue) ailerons servos. ELAC #1 is primary in roll, ELAC #2 is primary in pitch. ELAC #1 controls outboard (Blue) elevator servos. ELAC #2 controls inboard left (Green) & inboard right (Yellow) elevator servos.
Sign off:AMM27-93-00-710-001.
Applicable deferrals:MEL27-93-01=ELEC.