- Aircraft configuration prior to reset:
On ground, with engines running, wheels chocked.
Circuit breakers to reset:None
Steps to clear warning:With engines running, set parking brake, use overhead pushbuttons to switch “OFF” engine hydraulics, when hydraulics are depressurized, select “OFF” ELAC #1 and #2 using overhead swich. After 3 seconds, switch ELAC #1 and ELAC #2 “ON”. After approx 15 seconds, select hydraulics back “ON”.
Reset duration:30 seconds.
Results of power up test or reset:Pass: Fault clears.
Fail: Fault remains.
Notes:Follow reset steps closely.
Sign off:AMM27-93-00-710-001.
Applicable deferrals:No MEL.