- Aircraft configuration prior to reset:
Aircraft on ground.
Circuit breakers to reset:
Steps to clear warning:
First, reset applicable ELAC pushbutton. If no help, open
associated breaker for 5 seconds. Pushbutton to remain in “ON” position during breaker reset.
Reset duration:
20 seconds.
Results of power up test or reset:Pass: Fault clears.
Fail: Fault remains.
Notes:
If fault is isolated to a servo, change the servo
valve first prior to changing the complete servo control.
Sign off:AMM27-93-00-710-001.
Applicable deferrals:MEL27-14-01=Aileron Servo Controls.
MEL27-14-02=Aileron indications on ECAM inop.