- Aircraft configuration prior to reset:
Aircraft on ground, Engines shut down.
Circuit breakers to reset:
Steps to clear warning:Open associated circuit breakers for 1 second, then close.
Reset duration:1 seconds.
Results of power up test or reset:Pass: Engine parameters return to nomral.
Fail: Fault remains.
Notes:Associated GCU or EGIU is at fault, There is a reset button on each GCU (Nose E&E).
Sign off:TSM24-22-00-810-805 (#1 engine parameter check).
TSM24-22-00-810-807 (#2 engine parameter check).
Applicable deferrals:MEL24-20-01=Engine Driven Generator.