- Aircraft configuration prior to reset:
None specfic.
Circuit breakers to reset:
Steps to clear warning:Turn “OFF” all RMP’s then turn “ON” to reset. If no help, reset associated ACP breakers.
Reset duration:120 seconds.
Results of power up test or reset:Pass: ACP functions normally.
Fail: Still will not change.
Notes:No notes at this time.
Sign off:AMM23-51-00-740-002.