- Aircraft configuration prior to reset:
Associated fault light illuminated on overhead pushbutton. Valve is amber on bleed page.
Circuit breakers to reset:None
Steps to clear warning:Select associated PACK “OFF”, then“ON” using overhead pushbuttons.
Reset duration:5 seconds.
Results of power up test or reset:Pass: Valve will show in-line green on bleed page.
Fail: Valve indication will be crossline amber.
Notes:To easily determine if the valve is faulty, disconnect the flow control valve cannon plug with bleed air present. Valve should open as per design.
Sign off:AMM21-61-00-710-001.
Applicable deferrals:MEL21-51-01=Flow Control Valve.
MEL21-52-01=Packs.